HOME > Products > Magnescale > PL81/PL82

| Specifications | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
This product might change without a previous notice for the improvement, confirm the function and the performance with the latest specifications. | ||||||||||
| Model | PL81 | PL82 | ||||||||
| -3 | -5 | -7 | -A | -B | -3 | -5 | -7 | -A | -B | |
| Head cable length | 3 | 5 | 7 | 10 | 15 | 3 | 5 | 7 | 10 | 15 |
| Mass(g) | 640 | 720 | 800 | 910 | 1050 | 640 | 720 | 800 | 910 | 1050 |
| Accuracy(20℃) | (50+10L/1000)μm(L:Measuring lengthmm)(when used with SL110/SL130.) | |||||||||
| Resolution | 10, 20, 25, 50, 100μm | |||||||||
| Alarm display | LED turns orange. (green for normal operation) | |||||||||
| Clearance | Max.1.5mm | |||||||||
| Maximum response speed | 300m/min | |||||||||
| Output circuit | Max.rated voltage:40V, Max.rated current:100mA | AB phase signal by line driver MC34C87(compliance) | ||||||||
| Power supply | DC10~30V | DC4.75-5.25V | ||||||||
| Consumption current | Max.70mA(2.1W) | Max.300mA(1.5W) | ||||||||
| Protective design grade | Equivalent to IP67 (exclude head cable) | |||||||||
| Operating temperature | 0℃~+45℃ | |||||||||
| Storage temperature | -20℃~+50℃ | |||||||||