HOME > Products > Magnescale > MJ620

| Specifications | ||
|---|---|---|
|
*1 The alarm function may not operate when an abnormal offset is generated due to a broken wire, etc *2 The MJ620 Interpolator meets the "applied standards" stated in the specifications table when fitted with the optional MZ5 metal case (see below). Make sure that the MJ620 is used with the MZ5 or like case with the same specifications as MZ5. This product might change without a previous notice for the improvement, confirm the function and the performance with the latest specifications. | ||
| Model | MJ620 | |
| Power supplyPower supply voltage | DC5V±5% | |
| Power consumption | 2.2W(when connected to PL101) | |
| Output interface | Line driver (EIA-422 compliance) | |
| Output | AB quadrature・Z phase・Alarm | |
| Number of divisions | 800, 400, 160, 80, 40, 32(Correspond to resolution 1, 2, 5, 10, 20, 25 μm) and 1/2 of this (But concurrent reference point not satisfied) | |
| Maximum response speed | Resolution:1μm | 6.4m/s(with phase difference of 100 ns) |
| 2μm | 16m/s(with phase difference of 100 ns) | |
| 5μm | 36.8m/s(with phase difference of 100 ns) | |
| 10μm | 56m/s(with phase difference of 100 ns) | |
| Phase difference | 100ns | |
| Alarm*2 | SIN COS signal : 0.6Vp-p~1.2Vp-p at 120 Ω load Reference signal : 0.2V~1.5V at 120 Ω load | |
| Input level | Speed alarm (minimum phase difference time or maximum response frequency); Level alarm (0.6 Vp-p or less); Minimum alarm time: approximately 400 ms | |
| System startup time | Within 0.5 seconds after the power comes on line | |
| Operating temperature | 0℃~45℃ | |
| Storage temperature | -20℃~60℃ | |
| Dimensions | 99×59×21(mm) ncluding protrusions | |
| Mass | 60 g | |
| Option | Output connector MZ2, Metal case MZ5*2 | |