Magnescale Co., Ltd. || Magnescale(R), Magnescale(R), Digital Gauge

HOME > Products > Magnescale > MJ100/110

MJ100/110Magnescale

MJ100/110 Magnescale

Features

High response speed interpolator unit for position control

  • Capable of 40 to 1000 divisions
  • Produces AB quadrature signals with a resolution from 2 μm to 125 μm, when used in combination with the optionally available DigirulerR PL25 head unit and the SL110/130 scale unit (scale signal wavelength: 5 mm), or with the PL60 and the SL331 scale unit (scale signal wavelength: 2 mm).
  • MJ100: Supply voltage 5 V input, Line driver (EIA-422 compliance) output
  • MJ110: Supply voltage 12 to 30 V input, Open collector (lOL=50 mA) output
  • MJ100 also generates U/ V/ W phase output with a period of reproduced DigirulerR signal (5 mm with PL25; 2 mm with PL60)

Specifications

Specifications

*1 These valuse for a minimum phase difference of 1 μs may vary depending on the output cable length.
*2 The alarm function may not operate when an abnormal offset is generated due to a broken wire, etc

This product might change without a previous notice for the improvement, confirm the function and the performance with the latest specifications.

ModelMJ100MJ110
Power supplyPower supply voltageDC5V(4.5V~6V)DC12V~30V(11V~31V)
Power consumption4W3W
Output interfaceLine driver (EIA-422 compliance)NPN open collector(IOL=50mA max.)
OutputAB quadrature・Z phase・UVW phases・AlarmAB quadrature・Z phase・Alarm
Number of divisions1000, 960, 800, 512, 500, 480, 400, 256, 240, 200, 128, 120, 100, 80, 64, 40 and 1/2 of each of these (which does not satisfy the synchronized reference point specifications.)
Maximum response speed1000divisions6kHz:when connected to PL25 1800m/min when connected to PL60 720m/min600Hz:when connected to PL25 180m/min when connected to PL60 72m/min*1
500divisions15kHz:when connected to PL25 4500m/min when connected to PL60 1800m/min1.5kHz:when connected to PL25 450m/min when connected to PL60 180m/min*1
200divisions42kHz:when connected to PL25 12600m/min when connected to PL60 5000m/min4.2kHz:when connected to PL25 1260m/min when connected to PL60 500m/min*1
120divisions70kHz:when connected to PL25 21000m/min when connected to PL60 8400m/min7.4kHz:when connected to PL25 2220m/min when connected to PL60 888m/min*1
Phase difference100ns1μs
Alarm*2Speed alarm (minimum phase difference time or maximum response frequency); Level alarm (0.4 Vp-p or less); Minimum alarm time: approximately 400 ms
System startup timeWithin 0.5 seconds after the power comes on line
Compatible head unitPL25or PL60
Operating temperature0℃~45℃
Storage temperature-20℃~60℃
Dimensions138×93×26(mm) ncluding protrusions
Mass350 g
AccessoriesManual・Output connector・connector cap・mounting screws・Ferrite core
OptionSET-P16-1 (for external reference point) Scale extension cable, external reference point extension cable, Output connector with cable

Dimensions

※Please contact our sales.

Contact

Manual

Product nameJapaneseEnglishDeutschSimplified ChineseTraditional Chinese
MJ100.110 Download Download Download

※Please contact our sales.

Contact

Catalog

MJ100/110 SeriesJapaneseMJ100/110 Catalog Japanese PDF
MJ100/110 SeriesEnglishMJ100/110 Catalog English PDF

※Please contact our sales.

Contact