HOME > Products > DigitalGauge > MG40

| Specifications | ||||||||
|---|---|---|---|---|---|---|---|---|
| Item | Conditions | Description | Remarks | |||||
|
This product might change without a previous notice for the improvement, confirm the function and the performance with the latest specifications. | ||||||||
| No. of connectable measuring units | Entire system | 1 to 100 units (Connection disabled aft er connection of 101st unit.) | Up to 24 connected MG42 hub units | |||||
| MG41main unit | 0~4units | |||||||
| MG42hub unit | 0~4units | |||||||
| Connectable measuring units | DK800A/DK800B series, DK10, DK25, DK50, DK100, DK110, DK155, DK205 | |||||||
| Connection cable length | Between MG41 main unit and MG42 hub unit Total cable length from MG41 main unit: Maximum 30 m(Maximum current: 4 A or less) | |||||||
| Resolution | Settable output data resolution and display resolution | |||||||
| Measuring unitsResolution(Input resolution) | 0.1μm | 0.1μm | 0.5μm | 1μm | 5μm | 10μm | ||
| 0.5μm | - | 0.5μm | 1μm | 5μm | 10μm | |||
| Measuring unit data import capacity | data transfer10Mbps | Maximum 10 | The data for one axis is counted as one data. | |||||
| Peak hold function | Calculation of maximum value | |||||||
| Peak value is not updated during pause. | ||||||||
| Output and display data are not updated during latching (internal data is updated) | ||||||||
| Recalculation of peak value is started by start function. | ||||||||
| Output data | Single axis | Current value | ||||||
| Addition and subtraction | Current value | Single axis calculation of an addition / subtraction axis is not possible(for preventing inconsistencies in calculation). | ||||||
| Conparetor function | Data for each axis (single axis | |||||||
| Comparator setting values | 2values | 4values | 8values | 16values | ||||
| No. of setting value groups | 16groups | 8groups | 4groups | 2groups | ||||
| Ethernet | 100Base-T (compliant with IEEE 802.3) 100 Mbps/10 Mbps/1 Mpbs (Auto-negotiation) Command input | |||||||
| Reset function | Current value for each axis is reset (by command). | |||||||
| Preset function | Value is preset to the current value of each axis (by command). | |||||||
| Datum point setting function | Datum point of each axis can be set (by command). | When master calibration function is not used | ||||||
| Reference point function | Reference point can be used to relocate the datum point of each axis (by command). | |||||||
| Master calibration function | Reference point can be used to perform master calibration for each axis (by command). | |||||||
| Measuring unit product information | The product information of the connected measuring unit can be acquired. | |||||||
| Command/setting enabled or disabled for each communication line | Ethernet | CC-Link | ||||||
| Command | Reset function | ○ | ○ | |||||
| Preset function | ○ | ○ | ||||||
| Datum point setting function | ○ | ○ | When master calibration function is not used | |||||
| Reference point function | ○ | ○ | ||||||
| Master calibration function | ○ | ○ | ||||||
| Comparator value setting | ○ | ○ | ||||||
| Comparator group number setting | ○ | ○ | ||||||
| Start | ○ | ○ | ||||||
| Pause | ○ | ○ | ||||||
| Latch | ○ | ○ | ||||||
| Data output | Current value・Peak value( All axis) | ○ | × | |||||
| Current value・Peak value( each unit) | ○ | ○ | ||||||
| Comparator result | ○ | ○ | ||||||
| Alarm( data transfer・Measuring units) | ○ | ○ | ||||||
| Soft ware version | ○ | ○ | ||||||
| Measuring unit product information | ○ | ○ | ||||||
| Comparator result | Input resolution | ○ | ○ | |||||
| Display・Resolution | ○ | ○ | ||||||
| Axis addition | ○ | ○ | ||||||
| Comparator mode (2, 4, 8, or 16 values in 1 group) | ○ | ○ | ||||||
| Power supplyPower supply voltage | Terminal input | DC12~24V(11~26.4V) | Use a power supply with a current that is 4 A or higher. (Recommended: +24 V) (for every six MG42 hub units) | |||||
| Power consumption | Note the connection conditions. | System total: Max. current 4A | ||||||
| When the maximum current is exceeded | ||||||||
MG41 main unit : 4 W | ||||||||
| Operating temperature/humidity | 0~+50℃(non condensing) | |||||||
| Storage temperature/humidity | -10~+60℃(20~90%RH) | |||||||
| Mass | MG41:300g MG42:250g | |||||||