DF805S Features

Slim, compact, and having a high resolution of 0.1 μm maximum The maximum response speed has also further advanced.

  • Measuring range: 5mm
  • Accuracy: 1 μm
  • Maximum resolution: 0.1 μm
  • Maximum response speed: 80 m/min
  • Built-in reference point
  • Excellent resistance to water and oil
  • Adopts a flexing-resistance cable
  • Achieved numbers of strokes: 92 million (full stroke sliding test 2 years passed as of March, 2014)

MF10 Features

Simple settings make operating easy. Threshold can be set by two clicks.

  • Input/output circuit: NPN output(Current sink) / PNP output(Current source)
  • Number of Go/NoGo judgment outputs: 2
  • External input: 1
  • Minimum display unit: 0.1μm
  • Power supply voltage: 10 to 30VDC, including ripple(p-p) 10%
  • Protection circuit: Power supply reverse polarity protection, output short-circuit protection, and output incorrect connection protection
  • Number of banks: 4

Specifications

DF805S series Specifications

Magnescale reserves the right to change product specifications without prior notice.

ModelDF805SR、DF805SFRDF805SLR、DF805SFLR
Measuring range5mm
Resolution0.1μm
Accuracy(at 20°C/68°F)1μm
Measuring force(at 20°C/68°F)Upward:0.35±0.25N
Horizontal:0.40±0.25N
Downward:0.45±0.25N
Maximum response speed80m/min
Reference pointat 1±0.5 mm position of spindle movement
Reference point response speed80m/min
OutputDedicated serial communication protocol
Spindle drivingSpring push
Achieved number of strokes92 million strokes (full stroke sliding test 2 years passed as of March, 2014)
Protective structureIP66IP54
When a ø4 mm tube is connected : IP67
Impact resistance100m/s2(20~2,000Hz)
Vibration resistance1,000m/s2(11ms)
Operating temperature0~55℃
Storage temperature-20~60℃
Power supply voltage+10 to +30V DC including ripple (p-p) 10%
Power consumption1.2 W or less
MassApprox. 30 g (not including cable parts and interpolation box)
Probe part cable length2m
Output cable lengthMax. 20 m (Use the optional CE34.)
FeelerProvided with a carbide ball tip Mount screw M2.5
AccessoriesInstruction Manual, 1 wrench,
1 hose elbow (only DF8**S*L**)
Tightening nut, clamp wrench, wave washer, stop pin (1 each) (only DF8**S*F**)
MF10 series Specifications
ModelMF10-P1MF10-P2
Type I/O circuit NPN output (current sink) PNP output (current source)
I/O Number of Go/NoGo judgment outputs 2
Number of external inputs 1
Minimum display unit 0.1μm
Power supply voltage+10 to +30V DC including ripple (p-p) 10%
Power consumption*1Power supply voltage 24 V normal mode: 2040 mW or less (Power consumption 85 mA or less)
Power-saving ECO mode: 1920 mW or less(Current consumption 80 mA or less)
Go/NoGo judgment output*2Load voltage: DC 30 V or less, open collector output type
Load current: the total of the two outputs must be 100 mA or less
Residual voltage and load current less than 10 mA: 1 V or less
Load current 10 mA to 100 mA: 2 V or less
Off-state current: 0.1 mA or less
Protection circuitPower supply reverse connection protection, output short-circuit protection and output reverse connection protection
Number of banks4 (Can be set 4 kinds of judgment value)
Ambient temperature range*3Operating: When lining up 1 or 2 digital tolerance indicators: 0°C to +55°C
Storage: -10°C to +60°C (with no icing or condensation)
Ambient humidity rangeOperating and storage: 35% to 85% RH (with no condensation)
Mass (main unit)Approx. 75 g
Cable length2m

*1. At a power supply voltage of 10 to 30 V, Normal mode: 2250 mW or less (power supply voltage 30 V: power consumption 75 mA or less / power supply voltage 10 V: power consumption 155 mA or less), power-saving ECO mode: 2100 mW or less (power supply voltage 30 V: power consumption 70 mA or less / power supply voltage 10 V: power consumption 135 mA or less)
*2. When lining up 4 or more digital tolerance indicators, the 2 output total is 20 mA or less.
*3 When used in a row, the operating ambient temperature range is 0°C to +50°C for 3 to 10 units, 0°C to +45°C for 11 to 16 units, and 0°C to +40°C for 17 to 30 units.

Magnescale reserves the right to change product specifications without prior notice.

Dimensions

Product name2D3D
DF805SR Download Download
DF805SFR Download Download
DF805SLR Download Download
DF805SFLR Download Download
MF10  Download  
CE34  Download  

*Please contact our sales department.

Contact

Manual

Product nameJapaneseEnglishCorrection
DF805S Download Download
MF10 Download Download Download

*Please read the MF10 instruction manual with correction.

*Please contact us if you cannot download the file.

Contact

Catalog

DF805S/MF10 SeriesJapaneseDF805S Catalog JapanesePDF
DF805S/MF10 SeriesEnglishDF805S Catalog EnglishPDF

*Please contact us if you cannot download the file.

Contact